SIA compliance report for The Integral Science Data Archive InterOperability System

Description:
INTEGRAL (The International Gamma-Ray Astrophysics Laboratory) is the second medium-sized mission of ESA's Horizon 2000 Science Programme. INTEGRAL is dedicated to the fine spectroscopy (E/deltaE = 500) and fine imaging (angular resolution: 12 arcmin FWHM) of celestial gamma-ray sources in the energy range 15 keV to 10 MeV with concurrent source monitoring in the X-ray (3-35 keV) and optical (V-band, 550 nm) energy ranges. The INTEGRAL payload consists of the two main gamma-ray instruments, the spectrometer SPI , the imager IBIS and two monitors, the X-ray monitor JEM-X and the optical monitor OMC . All instruments are coaligned, covering simultaneously a very broad energy range for the study of high energy astrophysical sources. The INTEGRAL Science Operations Centre (ISOC) is responsible for the definition of scientific operations including the instrument configuration for each observation, the mission planning and implementation of the observing programme.
Not compliant
Service URL


Metadata query: link to metadata query
Metadata query specificiation here

Input Parameter Required Present
Regular parameters:
POS MUST Yes
SIZE MUST Yes
INTERSECT MAY No
NAXIS MAY No
CFRAME MAY No
EQUINOX MAY No
CRPIX MAY No
CRVAL MAY No
CDELT MAY No
ROTANG MAY No
PROJ MAY No
FORMAT MUST No
Service specific parameters
POS_EQ_RA_MAIN MAY Yes
POS_EQ_DEC_MAIN MAY Yes
ID_TARGET MAY Yes
RETURN_TYPE MAY Yes
OBS_ID MAY Yes


Data query: typical data query Crab_nebula
Successful data query specificiation here


Field UCD Required Present Required
datatype
Actual
datatype
Regular fields:
VOX:Image_Title MUST Yes char char
INST_ID SHOULD No char
VOX:Image_MJDateObs SHOULD No double
POS_EQ_RA_MAIN MUST Yes double double
POS_EQ_DEC_MAIN MUST Yes double double
VOX:Image_Naxes MUST Yes int int
VOX:Image_Naxis MUST Yes int int
VOX:Image_Scale MUST Yes double double
VOX:Image_Format MUST Yes char char
VOX:STC_CoordRefFrame SHOULD No char
VOX:STC_CoordEquinox MAY No double
VOX:WCS_CoordProjection SHOULD No char
VOX:WCS_CoordRefPixel SHOULD No double
VOX:WCS_CoordRefValue SHOULD No double
VOX:WCS_CDMatrix SHOULD Yes double double
VOX:BandPass_ID SHOULD No char
VOX:BandPass_Unit SHOULD No char
VOX:BandPass_RefValue SHOULD No double
VOX:BandPass_HiLimit SHOULD No double
VOX:BandPass_LoLimit SHOULD No double
VOX:Image_PixFlags SHOULD No char
VOX:Image_AccessReference MUST Yes char char
Service specific fields:
OBS_ID MAY YES char
VOX:OBS_START_TIME MAY YES char
VOX:OBS_END_TIME MAY YES char


Error Response: typical error response
(this is a clearly erroneous query which should return a VOTABLE error message)
Correct error response specificiation here
WARNING: No VOTABLE returned on error response
WARNING: No RESOURCE returned on error response
WARNING: No INFO returned on error response